In the USA, there are four most common types of premarket submissions: 

  • HDE (Humanitarian Device Exemption)

The 510(k) and PMA submission routes depend on the Device Class. 

For reference: FDA device classes** 

Equivalence in US – How to use it!-Eclevar-CRO

What is the 510(k) route, also called the Pre-Market Notification?  

If you wish to place a device on the US market and a Premarket Approval Application is not required – you must submit a 510(k) to the FDA *note there are exemptions & limitations to this ‘.9 of the device classification regulation chapters (21 CFR 862.9, 21 CFR 864.9)’ 

The main principle of this submission is to demonstrate that your product is as ‘safe and effective’ (substantially equivalent) to a device that is legally marketed in the US. The legally marketed device or devices are referred to as the predicate devices(s). 

You cannot market your device until the FDA have deemed it to be substantially equivalent – this decision is usually made within 90 days and is solely based on the information you provide in your submission.  

510(k) submission cleared by the FDA are published – usually in the first week of the following month.   

Equivalence in US – How to use it!-Eclevar-CRO

What are the criteria for substantial equivalence in US? 

What counts as a predicate device 

  • A legally marketed device that was marketed prior to May 28th 1976 
  • A device that had been reclassified from Class III to class II or I 
  • A device that was found to be substantially equivalent through a 510(k) submission 
  • A device granted marketing authorisation through the De Novo classification process

     

It is possible to use more than one predicate,; times this is utilized include: 

  • When combining features from two or more predicate devices with the same intended use into a single new device 
  • Where the device under evaluation has more than one intended use 
  • Where a device has more than one indication for use under the same intended use

     

If there is no appropriate predicate device, then manufacturers will need to submit a De Novo request or for high risk products a Premarket Approval may be required.  

The approach to demonstrating equivalence is different to the EU/UK and has two key considerations: intended use and technological characteristics.  

Below shows the two different ways in demonstrating this.  

What are the criteria for substantial equivalence in US?

There are less strict requirements within the regulations when compared to the EU approach – however the principles are very much the same. The similarities and the differences must be clearly set out and evaluated.   

There must be clear evidence to demonstrate the use of the predicate device(s) is valid and that there is assurance that the safety and effectiveness are substantially equivalent.  

The onus is on the manufacturer to ensure this is presented in a robust and scientifically valid way.  

This installment will turn the attention to the US and the FDA’s use of equivalence in us

Common reasons for Not Substantially Equivalent (NSE) decision

These fall in to 2 categories – (1) FDA decision that the device is Class III and cannot be reviewed through 510(k); (2) inadequacies in evidence provided in the submission 

Eclevar MedTech a global CRO can help manufacturers understand the requirements for market entry to US

If an NSE decision is given – the manufacturer is given the chance to respond to the FDA determination & the deficiencies noted.  

Take home message: 

  • This is a useful route for the US market that offers more timely access to market 
  • It should not be seen as a short cut – assurance around safety and performance is critical. 
  • Provide clear and robust evidence in the submission 
  • Only use legally marketed devices as a predicate  
 

We hope this has helped set out the requirements and considerations when looking to use the FDA’s 510(k) route. For further guidance on a evaluating substantial equivalence for your device you can refer to the FDA’s guidance  

Eclevar MedTech a global CRO can help manufacturers understand the requirements for market entry to US. Our team works as an extension team of medical affairs and regulatory affairs sponsor offering customized service with dedicated staffing clinical or regulatory expert with over 20 years’ experience who can help navigate you to the effective solution. Please contact us at clientcare@eclevar.com to learn more.