Medical device acquisitions

Clinical evidence due diligence for a medical device acquisition

Choose the device and commercial claim the buyer is relying on. Then trace that claim to a study, a device version and a result that someone outside the seller’s team can reproduce.

What belongs in the data room?

Start with the products and territories in the transaction. For each material model, collect the current instructions for use, product or catalogue identifiers, applicable certification scope and the dated clinical evaluation. Ask for the changes that distinguish it from earlier generations. Record which markets and intended uses each document covers.

Next, choose a single claim from the seller’s presentation. Check its wording against the intended use. Ask for the study protocol, analysis population, endpoint definition, follow-up, dated result and any limitations noted in the clinical evaluation. For an EU device, Article 61 and Annex XIV of the Medical Device Regulation connect the clinical evaluation to the device’s intended purpose and clinical benefits.

How to test a hip implant survival claim

Suppose a seller describes ten years of revision-free experience for a hip system. Its current liner entered the market three years ago. Ask which stem, cup, liner, bearing and fixation method contributed to the reported result, when each configuration was used and how many patients remained at risk at ten years.

The National Joint Registry’s 2025 hip report gives a practical illustration. Table 3.H8(a) breaks down revision estimates by implant combination and bearing, reports uncertainty and flags time points with fewer patients still under observation. Use the dated row, its definitions and its follow-up to test the seller’s interpretation. Consult the latest report for the current assessment.

Record a finding the buyer can act on. The older configuration has a ten-year estimate, subject to its confidence interval and follow-up. The newer liner has three years of potential direct observation. Ask the clinical team to show which design changes could affect performance and whether evidence supports applying the older experience to the new configuration. Request separate evidence for a claim about pain or function.

Four checks that turn a claim into a decision

Evidence to request and how to use it in the acquisition review
CheckWhat to requestHow the answer changes the review
Product match Catalogue numbers, dates of design changes and the mapping to the study or registry. If a model cannot be identified, record exactly which configurations the evidence can support.
Outcome and follow-up Endpoint definition, population, analysis date, number observed at the claimed duration and uncertainty. If a follow-up measure is missing, scope a record review or additional follow-up around that specific question.
Access to the result A reproducible analysis, its source and the applicable registry or study agreement. Ask the data owner and transaction counsel to confirm which analyses and permitted uses carry through closing.
Open commitments Current post-market follow-up plan, outstanding findings, due dates and responsibility for delivery. Separate funded work from work that needs a feasibility assessment or supplier quote.

What the deal team should take away

Prepare one entry per material claim. Include the exact device and territory, what the evidence presently shows, any unresolved assumption and the underlying dated source. Give each open item a named owner, a due date and a practical route to resolution.

For the illustrative hip system, the next step may be a component crosswalk and an updated analysis of the marketed configuration. If the registry cannot identify the liner, obtain a feasibility estimate for a different data source. The investment team can then see which assumptions are substantiated and which still depend on additional work.

Scope a clinical evidence review

Bring the device family, target markets, decision date and the claim you need checked. These details help define the review and the evidence specialists required. Arrange secure document access separately when needed.