Summary of Safety and Clinical Performance (SSCP) writing under EU MDR

For Class III and implantable devices, the SSCP is the public summary of your clinical evidence. Eclevar writes it from the CER and the technical documentation, in language the intended user can follow, and keeps it in step with every update.

The SSCP is drafted by the manufacturer, validated by the Notified Body and made public in EUDAMED. Because it condenses the clinical evaluation, the IFU and the risk file into a few pages, it is also where inconsistencies between those documents become visible. We write and review SSCPs alongside the clinical evaluation report, so the two say the same thing.

  • New SSCPs drafted from the CER, IFU and risk file for MDR certification
  • Updates after a CER, PMCF or PSUR update, with a version history
  • EUDAMED readiness for the move of SSCP uploads to manufacturers
Article 32

Which devices need an SSCP, and what it has to contain

Article 32 of the MDR requires an SSCP for implantable devices and for Class III devices, other than custom-made or investigational devices. The draft is part of the documentation submitted to the Notified Body, which validates it before it is made public.

What Article 32 requires it to include

  • Identification of the device and the manufacturer, including the Basic UDI-DI and, once issued, the SRN
  • The intended purpose, indications, contraindications and target populations
  • A description of the device, its previous generations or variants and its accessories
  • Possible diagnostic or therapeutic alternatives
  • The harmonized standards and common specifications applied
  • The summary of the clinical evaluation and relevant information on PMCF
  • The suggested profile and training for users
  • Residual risks, undesirable effects, warnings and precautions

How it has to work in practice

  • Written so the intended user and, where relevant, the patient can understand it
  • Consistent with the CER, the IFU and the risk management file it summarizes
  • Referenced on the label or in the IFU, so users can find it in EUDAMED
  • Reviewed, and updated if needed, whenever the PMCF evaluation report and the PSUR are updated
MDCG 2026-4

SSCP uploads are moving from the Notified Body to the manufacturer

Use of the first four EUDAMED modules became mandatory on May 28, 2026. MDCG 2026-4, a position paper first published in June 2026 and revised in October 2026, sets out how SSCPs are handled from there.

  1. Now: the Notified Body uploads

    Until the new functions reach EUDAMED Production, the Notified Body uploads the master SSCP, without translations, when it registers a certificate or its update.

  2. Next: the manufacturer uploads

    Under the revised MDCG 2019-9, the manufacturer uploads the master SSCP and its translations and has to make sure the uploaded version is the one the Notified Body validated. Deployment in Production is planned for December 2026.

  3. Devices already on the market

    For devices placed on the market before mandatory use of the UDI/Devices module, MDCG 2026-4 asks manufacturers to upload their SSCPs as early as possible and no later than March 27, 2027.

In practice, someone on your side now owns the validated master, its translations and the version history. If that file trail is not clean, the upload step is where it shows.

In our experience

Where SSCPs usually draw questions

Most questions on an SSCP trace back to the documents it summarizes rather than to the SSCP itself.

Figures that do not match the CER

Performance and safety figures quoted in the SSCP that differ from the CER, or come from an earlier version of it.

Claims the IFU does not make

Indications, target populations or benefits worded differently from the IFU and the labeling.

A patient section written for clinicians

Text copied from the clinician section instead of being written for patients, where a patient section is relevant.

Residual risks out of step

Undesirable effects and warnings that no longer match the risk management file or the IFU.

No trigger for updates

An SSCP that is not reviewed when the PMCF evaluation report or the PSUR changes.

Translations that drift

Translated versions that no longer match the validated master after an update.

Fixed-scope engagements

Two SSCP engagements with a defined scope

Each engagement has a scope agreed in writing after a short scoping call and ends with documents your team and your Notified Body can work from.

New SSCP for MDR certification

You send

  • The CER and CEP
  • The IFU, the labeling and the risk management file
  • The PMCF plan and any PMCF evaluation report
  • The Basic UDI-DI, the SRN and the device variants

You receive

  • An SSCP draft structured to MDCG 2019-9, with a section for users and, where relevant, a section for patients
  • A cross-reference table linking each statement to its source document
  • A list of the inconsistencies found between the source documents
  • Support with the Notified Body's questions on the draft

Request a new SSCP

SSCP update and EUDAMED readiness

You send

  • The validated SSCP and its translations
  • The updated CER, PMCF evaluation report or PSUR
  • Your EUDAMED actor and device registration details

You receive

  • An updated SSCP with a tracked version history
  • A check that the master and each translation match the validated version
  • An upload checklist for the manufacturer upload step under MDCG 2026-4

Discuss an SSCP update

Fees are quoted after the scoping call, once the device class, the number of variants and the languages are known.

FAQ

Questions manufacturers ask about the SSCP

Does a Class IIb device need an SSCP?

Only if it is implantable. Article 32 applies to implantable devices and to Class III devices, other than custom-made or investigational devices. A non-implantable Class IIb device does not need one.

Who uploads the SSCP to EUDAMED?

For now, the Notified Body uploads the master SSCP, without translations, when it registers the certificate. MDCG 2026-4 moves that task to the manufacturer, who uploads the master and its translations once the new EUDAMED functions are in Production, planned for December 2026.

Does every SSCP need a section for patients?

The SSCP has to be clear to the intended user and, if relevant, to the patient. MDCG 2019-9 sets out when a section for patients is expected, for example for implantable devices that come with an implant card. We confirm whether your device needs one at scoping.

How often does the SSCP need updating?

For Class III and implantable devices, the PMCF evaluation report and the PSUR are updated at least annually. MDCG 2019-9 asks for the SSCP to be reviewed at the same time and updated if needed, so its clinical and safety information stays correct and complete.

Can you write the SSCP if another provider wrote our CER?

Yes. We start by reading the CER and its source documents. Where the SSCP cannot be written consistently with them, we list the gaps for you before drafting.

Next step

Have your SSCP read against your CER before the Notified Body reads it

Send the device class, the current CER and IFU, and where you are in certification. We aim to respond within one business day.

Scope and limitations

Eclevar prepares and reviews SSCP drafts and supports manufacturers with the EUDAMED upload. The SSCP is validated by the Notified Body, and no validation or certification outcome is implied. Regulatory references on this page are current as of November 2026.

Reforming Clinical Evaluation of Medical Devices in Europe