CGM CER

Clinical evaluation reports for continuous glucose monitoring systems

Clinical evaluation plans and reports for CGM sensors, apps and connected systems under the EU MDR. Accuracy is only the start: the CER has to show performance across glucose ranges, populations and wear time, and what it means for the people who act on the readings.

Three questions that set the evidence

Who wears it?

Type 1 or type 2 diabetes, children, pregnancy or hospitalized patients, each with its own evidence needs.

What decisions does it drive?

Trend review, treatment decisions without a fingerstick, alerts, or input to an insulin pump.

How long does each sensor last?

Accuracy has to hold from the first day of wear to the last.

A written gap review answers all three before any writing starts.

Work aligned withEU MDR 2017/745 Annex XIVMEDDEV 2.7/1 rev 4ISO 14155:2026IEC 62304IEC 62366-1

Where you are

Three situations we are usually called in for

The scope depends on the stage of your file. Each engagement starts with a review of what exists, so the work covers the gap rather than the whole document by default.

First CE marking

A new sensor or a first MDR file: clinical evaluation plan, accuracy study design, literature protocol and a CER written to Annex XIV Part A.

New indication or population

Extension to children, pregnancy or hospital use, or a longer wear time: what the existing data cover, and which new study the claim needs.

Notified body findings

A deficiency list on the clinical evaluation: each finding mapped to the evidence that answers it, with a written response and updated CER sections.

Classification

The intended use decides the class and the evidence

CGM systems are commonly placed in Class IIb under the MDR. The sensor, the app and any connection to an insulin pump each need a classification rationale, and the strictest class sets the evidence.

System elementWhat drives the classWhat it changes for the CER
Sensor and transmitterMonitoring of glucose, a parameter whose variations can put the patient in immediate dangerAccuracy across the full glucose range, with particular attention to hypoglycemia.
Display app or readerSoftware that monitors physiological processes, classified with the system or in its own rightPerformance of alerts, trend arrows and data display on each supported platform.
Connection to insulin deliveryInput to a device that doses insulinReliability of the data link and accuracy at the values that trigger dosing decisions.
Non-adjunctive useTreatment decisions without a confirmatory fingerstickAccuracy strong enough to support dosing decisions in the intended population.

The classification rationale is settled with your notified body. The CER is written for the system as it will be used, including every claim on connectivity and non-adjunctive use.

Performance

What a CGM CER has to show

Accuracy metrics describe the sensor. The clinical evaluation has to show that its performance supports the decisions people make with it.

Accuracy across glucose ranges

Agreement with a reference method in low, normal and high glucose ranges, not only an overall average such as MARD.

Accuracy over the wear period

Performance on the first day, during wear and at the end of the sensor's life, including warm-up and calibration.

Alert performance

How reliably hypoglycemia and hyperglycemia alerts fire, and how often they fire without reason.

Interferences and conditions of use

Effects of medications, physical activity, compression and skin conditions named in the instructions.

Clinical benefit

Outcomes such as time in range, HbA1c or hypoglycemia events, compared with current monitoring practice.

Reviewer findings

What notified bodies flag in CGM CERs

These findings recur in glucose monitoring files. The gap review tests for each one before submission.

Overall accuracy only

A single average accuracy figure that hides poor performance in hypoglycemia or at the end of wear.

Population not covered

Children, pregnancy or hospitalized patients in the indications without matching study data.

Reference method not justified

Comparator measurements whose timing, method or uncertainty are not described.

Acceptance criteria not set

Accuracy reported without criteria defined in advance. EU-level criteria for CGM accuracy are still under discussion, so the CER has to justify its own.

Connectivity claims unsupported

Pump or app compatibility claimed without evidence on the versions and platforms listed.

Generic PMCF plan

No plan to track real-world accuracy, sensor failures and complaints after launch.

Data sources

Where the clinical data can come from

Most CGM files combine a dedicated accuracy study with other sources. The clinical evaluation plan states which source answers which question.

Clinical performance

Accuracy study

A prospective study against a reference method, with in-clinic sessions that cover the glucose range and the full wear period.

Literature

Systematic search and appraisal

Published data on the device and on the state of the art in glucose monitoring, appraised with a documented protocol.

Post-market data

PMCF and real-world data

Real-world accuracy where fingerstick values are logged, sensor failure rates and complaints.

Registries

Diabetes registries

National and clinic registries that capture glycemic outcomes, when they identify the device used.

How it runs

From gap review to notified body questions

Each step ends with a written output you can review. A senior reviewer challenges the file before it goes to your notified body.

Step 1

Gap review

Existing CER, claims, classification rationale and data inventory, with a written list of gaps.

Step 2

Evidence plan

Clinical evaluation plan, literature protocol and a data source for each open question.

Step 3

State of the art

Current glucose monitoring practice and its alternatives, used to set acceptance criteria and judge benefit.

Step 4

Appraisal and writing

Data appraised and the CER written to Annex XIV Part A, traceable to each source.

Step 5

Reviewer challenge

Senior review against the findings notified bodies raise, before submission.

Step 6

Alignment and support

PMCF plan, SSCP where required and instructions for use aligned with the CER, and support with notified body questions.

No timeline is quoted before the gap review, because it depends on the data that already exists.

Deliverables

What you receive

Two fixed-scope reviews are available as a first step, each with a written deliverable. Full CER authoring is scoped after them.

Fixed scope

CER gap review

  • Review of the current CER and clinical evaluation plan
  • Claims checked against the evidence and the class
  • Equivalence and data-on-device assessment
  • Written gap list, ranked by review risk

Fixed scope

Response to notified body findings

  • Each finding mapped to the evidence that answers it
  • Written response text
  • Updated CER sections
  • Support during follow-up questions

Scoped after review

Full CER and related documents

  • Clinical evaluation plan and literature protocol
  • Clinical evaluation report
  • PMCF plan and PMCF evaluation report
  • SSCP where required
  • PMCF surveys where useful

Fixed-scope reviews are quoted after a scoping call. See the clinical evaluation report services page for other device types.

Track record

The numbers behind the method

Of the 56 studies ECLEVAR has delivered, 21 are PMCF studies and registries. The methods on this page come from that work.

56

Studies delivered

As of November 2026

By study phase

Studies by country

France18
Germany12
United Kingdom10
Italy8
Spain6
Nordic market3
Ireland2
Other5

A study running in several countries is counted once in each country.

400+

Devices assessed by former notified body reviewers now in ECLEVAR leadership

9

Clinical monitors (CRAs)

4

Project managers

3

Medical writers

3

Data management and biostatistics

2

Quality assurance

Clients

Medical device manufacturers we work with

Manufacturers of wound care products, implants, monitoring systems and dental devices use ECLEVAR for clinical investigations, PMCF and registries. More in our client success stories.

Client: RegenLab

Multicountry prospective PMCF in wound care

A two-cohort program in chronic wounds, diabetic foot ulcers and venous leg ulcers, run across European sites under one protocol and one data model.

160

participants

14

sites

5

European countries

Client: Perouse Medical, Vygon Group

Six registered observational studies across a vascular portfolio

ECLEVAR structured the program architecture and supports delivery. Intended evidence use: clinical evaluation and PMCF.

6

registered observational studies

3

device families

1,150+

subjects

5 years

follow-up

Team

The people who write and challenge your file

A senior team designs the accuracy evidence, writes the clinical evaluation and challenges it before submission.

Portrait of Pierre-Marie Boutanquoi

Pierre-Marie Boutanquoi

Head of Medical Writing

Clinical evaluation methodology, literature strategy, evidence architecture and regulatory gap analysis across therapeutic areas.

Portrait of Sébastien Meier Piantanida

Sébastien Meier Piantanida

Head of Data Management and Biostatistics

Data architecture, EDC configuration, data quality control and statistical analysis for clinical performance studies.

Portrait of Chems Hachani

Chems Hachani

Founder and CEO

Sets the evidence strategy with the sponsor and stays accountable for delivery from first scoping call to final report.

Portrait of Karina Schönborn

Karina Schönborn

Business Development Lead

Your first point of contact for scoping, budget scenarios and proposals.

ECLEVAR leadership includes former notified body reviewers; the full team is on the leadership page. Platinum Award · CVBF & MILO Health, xShare / EUCROF EHDS & Clinical Research Open Call. The award recognizes the submitted data use case and is not an evaluation of CRO services.

Questions

What manufacturers ask before they start

Is MARD enough to show accuracy?

No. A single average hides where the sensor performs poorly. Notified bodies and clinicians look for accuracy by glucose range, by day of wear and by population, with agreement rates and error grid analysis against a reference method.

Do we need a new clinical study for a pediatric indication?

Usually, unless existing data already include children in the age range claimed. Accuracy and wear in children differ from adults, and the CER has to show performance in the population on the label.

Can we use our U.S. accuracy study in the EU CER?

Often, as a central piece of evidence, when the device version, population and reference method are applicable to the EU claims. The CER explains any differences and adds data where the EU indications go further.

How are connected insulin pump claims handled?

Each compatibility claim needs evidence on the specific pump, app version and communication path. The clinical evaluation also covers what happens when the data link fails.

Who stays responsible for the clinical evaluation?

The manufacturer. ECLEVAR plans, writes and challenges the documents, and supports you during the review. The conclusions on benefit-risk and conformity remain yours.

Client testimonial, publications and recordings

A client testimonial, two Notified Body white papers, a webinar and a podcast

RegenLab describes the PMCF program Eclevar runs for it. The two white papers on EU MDR clinical evidence were each co-authored by Eclevar with a Notified Body, and the recordings are hosted by Eclevar.

Client testimonial · RegenLab

RegenLab on its PMCF program with Eclevar

Antoine Turzi, CEO of RegenLab, on the randomized PMCF study run across 14 sites in 5 EU countries.

Watch the testimonial

White paper · BSI and Eclevar

Mastering EU MDR Clinical Evidence

Covers how Clinical Evaluation Reports are structured, how PMCF studies and registries are planned, and how legacy devices move to the EU MDR.

Authors: Chems Hachani, Founder and CEO, Eclevar MedTech, with BSI as co-authoring organization.

Request the white paper

White paper · TÜV SÜD · September 2026

Medical Breakthrough Devices (BtX)

Covers the EU pathway for Breakthrough Devices set out in MDCG 2025-9, and how clinical evidence is planned across the pre-market and post-market phases.

Authors: Dr. Langhit Kurar, Clinical Reviewer, TÜV SÜD, and Dr. Nikhil Khadabadi, Eclevar MedTech, Chief Medical Officer at publication.

Read on tuvsud.com

Webinar replay · PMCF

PMCF under the MDR: notified body insights and survey best practices

A recorded session on planning PMCF under the MDR, covering notified body insights, survey best practices and implementation.

Watch the webinar replay

Podcast · Combination products

Why are combined drug-device studies still split across two systems in Europe?

Chems Hachani talks with Dr. Fatima Sanfourche, PhD, Global Senior Director for QA & RA Compliance for Medical Devices, Combination Products & eHealth at Bayer and Scientific Board Member of Eclevar MedTech.

Listen to the podcast series

Co-authorship of a publication does not imply endorsement of Eclevar services by any Notified Body and has no bearing on any conformity assessment.

Next step

Send the CER you have, or the findings you received

We will tell you which gaps matter most for your device's class and claims, and what it would take to close them.

We aim to respond within one business day. A confidentiality agreement can be signed before you share any document.

Share the file

Current CER, claims list, instructions for use and any notified body findings.

Gap review

A written list of gaps, ranked by review risk.

Scope and plan

An agreed scope for the CER work and the evidence plan behind it.