Respiratory device CER

Clinical evaluation reports for respiratory devices under the EU MDR

CER writing, updates and notified body responses for ventilators, CPAP and other positive airway pressure devices, oxygen therapy equipment, nebulizers and respiratory monitors. We check what the device claims, which rule classifies it and whether the clinical data cover the patients and settings on the label.

Three questions that set the evidence

Who is the patient?

Critical care, home ventilation, sleep apnea or chronic respiratory disease, each with its own risks and outcomes.

Where is it used?

Intensive care, transport, hospital ward or home, by trained staff or by lay users.

What does it deliver or measure?

Ventilatory support, pressure, oxygen, aerosolized medication or a physiological measurement.

A written gap review answers all three before any writing starts.

Work aligned withEU MDR 2017/745 Annex XIVMEDDEV 2.7/1 rev 4ISO 80601-2-12ISO 80601-2-70IEC 62366-1

Where you are

Three situations we are usually called in for

The scope depends on the stage of your file. Each engagement starts with a review of what exists, so the work covers the gap rather than the whole document by default.

First MDR CER

A new respiratory device or a first MDR file: clinical evaluation plan, literature protocol, state of the art, appraisal and benefit-risk, written to Annex XIV Part A.

MDD to MDR update

A legacy CER rebuilt for the MDR, often for a device on the market for years: data on the device itself, post-market data organized as clinical evidence, and a PMCF plan that targets what remains open.

Notified body findings

A deficiency list on the clinical evaluation: each finding mapped to the evidence that answers it, with a written response and updated CER sections.

Classification

The class decides how much evidence the CER must carry

Most respiratory devices are active devices classified under Rules 9 to 12 of Annex VIII. Breathing circuits and interfaces follow their own rules. The intended purpose and the setting decide the class.

Device typeUsual MDR rule and classWhat it changes for the CER
Critical care ventilators and home ventilators for ventilator-dependent patientsRule 12, Class IIbClinical data on ventilation performance and safety in the intended patients, with alarm and failure scenarios addressed.
CPAP and other positive airway pressure devices not intended for critical careRule 12, often Class IIaTherapy effectiveness and adherence in the intended population, compared with the state of the art.
Nebulizers and other devices that administer medicinal productsRule 12, Class IIa or IIbAerosol delivery performance with the medicinal products named in the instructions, and its clinical relevance.
Oxygen concentrators and oxygen therapy equipmentRule 12, Class IIa or IIb depending on intended useOxygen delivery performance in the settings of use, and safety when supply fails.
Spirometers, pulse oximeters and respiratory monitorsRule 10, Class IIa, or IIb for vital parameters with immediate dangerMeasurement accuracy against a reference method, and performance at the thresholds that drive clinical decisions.
Breathing circuits and patient interfacesRule 2 or Rule 5, usually Class IIaCompatibility with the devices they connect to, and performance claims such as leak or dead space.

Class IIb active devices that administer or remove a medicinal product can fall under the clinical evaluation consultation procedure with an expert panel (Article 54), unless an exemption applies. We check this early, because it changes how the CER has to be written.

Evidence

What respiratory CERs have to show

Bench testing against the device standards establishes performance. The clinical evaluation has to show what that performance means for the patients on the label.

Performance in the intended population

Data from the patients named in the indications, for example pediatric, neonatal or obese patients when they are included.

Safety in failure and alarm scenarios

How the device and its alarms behave when ventilation, power or gas supply is interrupted, and what that means clinically.

Effectiveness of the therapy

Clinical outcomes such as gas exchange, symptom control or adherence, against current practice.

Use by lay users at home

Usability evidence and real-world data when the device is used outside a hospital by patients or carers.

Compatibility

Evidence that the device performs with the circuits, interfaces, humidifiers and medicinal products listed in the instructions.

Reviewer findings

What notified bodies flag in respiratory CERs

These findings recur in respiratory device files. The gap review tests for each one before submission.

Bench data presented as clinical data

Compliance with device standards used in place of clinical evidence on outcomes and safety in patients.

Population not covered

Indications that include patient groups for which no clinical data is presented.

Equivalence not demonstrated

Another device cited as equivalent without a comparison of software, control algorithms and clinical characteristics.

State of the art missing or dated

No current description of standard respiratory care and its alternatives, so the benefit cannot be judged.

Vigilance data not used

Complaints, incidents and field safety actions left out of the clinical evaluation, or not reconciled with the risk file.

Generic PMCF plan

A plan that does not target the residual risks and open questions identified in the CER.

Data sources

Where the clinical data can come from

Most respiratory device files combine several sources. The clinical evaluation plan states which source answers which question.

Literature

Systematic search and appraisal

A documented search protocol, appraisal criteria and data extraction, written so that another reviewer could reproduce them.

Equivalence

An equivalent device

Demonstrated on technical, biological and clinical characteristics, including software and control algorithms, with the access to data the MDR requires.

Post-market data

Vigilance, registries and PMCF

Complaints, incidents, device usage data where available, registries, and PMCF studies or surveys.

Clinical investigation

New clinical data

A pre- or post-market investigation when the other sources cannot carry the claims, for example a new ventilation mode or a new population.

How it runs

From gap review to notified body questions

Each step ends with a written output you can review. A senior reviewer challenges the file before it goes to your notified body.

Step 1

Gap review

Existing CER, claims, classification rationale and data inventory, with a written list of gaps.

Step 2

Evidence plan

Clinical evaluation plan, literature protocol and a data source for each open question.

Step 3

State of the art

Current respiratory care guidelines and alternatives, used to judge the benefit and the acceptability of risk.

Step 4

Appraisal and writing

Data appraised and the CER written to Annex XIV Part A, traceable to each source.

Step 5

Reviewer challenge

Senior review against the findings notified bodies raise, before submission.

Step 6

Alignment and support

PMCF plan, SSCP where required and instructions for use aligned with the CER, and support with notified body questions.

No timeline is quoted before the gap review, because it depends on the data that already exists.

Deliverables

What you receive

Two fixed-scope reviews are available as a first step, each with a written deliverable. Full CER authoring is scoped after them.

Fixed scope

CER gap review

  • Review of the current CER and clinical evaluation plan
  • Claims checked against the evidence and the class
  • Equivalence and data-on-device assessment
  • Written gap list, ranked by review risk

Fixed scope

Response to notified body findings

  • Each finding mapped to the evidence that answers it
  • Written response text
  • Updated CER sections
  • Support during follow-up questions

Scoped after review

Full CER and related documents

  • Clinical evaluation plan and literature protocol
  • Clinical evaluation report
  • PMCF plan and PMCF evaluation report
  • SSCP where required
  • PMCF surveys where useful

Fixed-scope reviews are quoted after a scoping call. See the clinical evaluation report services page for other device types.

Track record

The numbers behind the method

Of the 56 studies ECLEVAR has delivered, 21 are PMCF studies and registries. The methods on this page come from that work.

56

Studies delivered

As of November 2026

By study phase

Studies by country

France18
Germany12
United Kingdom10
Italy8
Spain6
Nordic market3
Ireland2
Other5

A study running in several countries is counted once in each country.

400+

Devices assessed by former notified body reviewers now in ECLEVAR leadership

9

Clinical monitors (CRAs)

4

Project managers

3

Medical writers

3

Data management and biostatistics

2

Quality assurance

Clients

Medical device manufacturers we work with

Manufacturers of wound care products, implants, monitoring systems and dental devices use ECLEVAR for clinical investigations, PMCF and registries. More in our client success stories.

Client: RegenLab

Multicountry prospective PMCF in wound care

A two-cohort program in chronic wounds, diabetic foot ulcers and venous leg ulcers, run across European sites under one protocol and one data model.

160

participants

14

sites

5

European countries

Client: Perouse Medical, Vygon Group

Six registered observational studies across a vascular portfolio

ECLEVAR structured the program architecture and supports delivery. Intended evidence use: clinical evaluation and PMCF.

6

registered observational studies

3

device families

1,150+

subjects

5 years

follow-up

Team

The people who write and challenge your file

A senior team plans, writes and reviews the clinical evaluation, with U.S. clinical input when the evidence plan uses U.S. data.

Portrait of Pierre-Marie Boutanquoi

Pierre-Marie Boutanquoi

Head of Medical Writing

Clinical evaluation methodology, literature strategy, evidence architecture and regulatory gap analysis across therapeutic areas.

Portrait of Chems Hachani

Chems Hachani

Founder and CEO

Sets the evidence strategy with the sponsor and stays accountable for delivery from first scoping call to final report.

Portrait of Dawn Heimer

Dawn Heimer, PhD

U.S. Clinical and Regulatory Consultant

Provides strategic input on U.S. medical-device clinical operations, regulatory considerations and real-world evidence programs.

Portrait of Karina Schönborn

Karina Schönborn

Business Development Lead

Your first point of contact for scoping, budget scenarios and proposals.

ECLEVAR leadership includes former notified body reviewers; the full team is on the leadership page. Platinum Award · CVBF & MILO Health, xShare / EUCROF EHDS & Clinical Research Open Call. The award recognizes the submitted data use case and is not an evaluation of CRO services.

Questions

What manufacturers ask before they start

Is compliance with ISO 80601 standards enough for a CER?

No. Device standards establish bench performance and basic safety. The clinical evaluation has to show clinical performance, safety and benefit in the intended patients and settings, using clinical data on the device or an equivalent one.

Does our ventilator CER need a clinical investigation?

Not necessarily. Class IIb devices can rely on literature, equivalence and post-market data when together they are sufficient. A clinical investigation becomes likely when the device introduces a new ventilation mode, a new population or a claim that existing data cannot support.

Does the expert panel consultation apply to our device?

It can apply to Class IIb active devices that administer or remove a medicinal product, unless an exemption applies. Whether it applies depends on the intended purpose and the substances involved, and it is settled with your notified body early.

How do we use years of post-market experience?

Post-market data can be strong evidence when it is organized: exposure estimated, complaints and incidents analyzed by type and severity, and results compared with the state of the art. Raw complaint counts without exposure or analysis carry little weight.

Can home-use data come from outside the EU?

Yes, when the population, setting and care pathway are shown to be applicable. Home care practice differs between countries, so the CER describes those differences and their effect.

Who stays responsible for the clinical evaluation?

The manufacturer. ECLEVAR plans, writes and challenges the documents, and supports you during the review. The conclusions on benefit-risk and conformity remain yours.

Next step

Send the CER you have, or the findings you received

We will tell you which gaps matter most for your device's class and claims, and what it would take to close them.

We aim to respond within one business day. A confidentiality agreement can be signed before you share any document.

Share the file

Current CER, claims list, instructions for use and any notified body findings.

Gap review

A written list of gaps, ranked by review risk.

Scope and plan

An agreed scope for the CER work and the evidence plan behind it.