Surgical robotics CER

Clinical evaluation reports for surgical robotic systems

Clinical evaluation plans and reports for robotic-assisted surgery systems and co-manipulated robots under the EU MDR. The evidence has to cover the system, its instruments and its software, and show results that hold as surgeons move through the learning curve.

Three questions that set the evidence

Which procedures are claimed?

Each specialty and procedure on the label needs clinical data or a justified extension.

What does the robot decide?

Teleoperation, guidance within boundaries, or steps performed with some autonomy.

Who operates it?

Surgeon experience, training and proctoring shape the outcomes the CER reports.

A written gap review answers all three before any writing starts.

Work aligned withEU MDR 2017/745 Annex XIVMEDDEV 2.7/1 rev 4IEC 80601-2-77IEC 62304IEC 62366-1

Where you are

Three situations we are usually called in for

The scope depends on the stage of your file. Each engagement starts with a review of what exists, so the work covers the gap rather than the whole document by default.

First CE marking

A new robotic platform: clinical evaluation plan, first-in-human and early clinical data, state of the art by procedure, and a CER written to Annex XIV Part A.

New procedures or specialties

An extension of the indications: what the existing data cover, and what each new procedure needs before it goes on the label.

Notified body findings

A deficiency list on the clinical evaluation: each finding mapped to the evidence that answers it, with a written response and updated CER sections.

Classification

System, instruments and software are classified one by one

Teleoperated surgical robots are generally placed in Class IIb under the MDR. Co-manipulated systems range from Class I to Class IIb depending on what they do. Instruments and software each need their own rationale.

System elementTypical MDR classWhat it changes for the CER
Teleoperated robotic system and consoleClass IIbClinical performance and safety by procedure, against laparoscopic or open surgery as the state of the art.
Co-manipulated or guidance robotClass I to IIb, depending on its functionEvidence that the guidance or boundary function improves accuracy or safety in the procedures claimed.
Robotic instruments and accessoriesClassified in their own right, often as surgically invasive instrumentsPerformance and safety of each instrument family, including reprocessing for reusable instruments.
Planning, navigation and imaging softwareRule 11, or the class of the device it drivesAccuracy of planning and registration, and its effect on surgical outcomes.

Where more than one rule applies, the strictest one sets the class. The classification rationale is settled with your notified body, and the CER is written for the system as it will be used.

Evidence

What a robotics CER has to show

Precision on the bench is easy to measure. The clinical evaluation has to show what it means for patients, procedure by procedure.

Outcomes by procedure

Complications, conversion to open surgery, reinterventions and functional outcomes for each procedure claimed.

Learning curve

How results change with surgeon experience, and how training and proctoring control that risk.

System malfunctions

Rates and consequences of system faults, instrument failures and procedure interruptions.

Comparison with the state of the art

Results set against laparoscopic, open or conventional navigated surgery for the same indication.

Use and ergonomics

Usability evidence for the surgical team, including setup, docking and emergency undocking.

Reviewer findings

What notified bodies flag in robotics CERs

These findings recur in surgical robotics files. The gap review tests for each one before submission.

Indications broader than the data

Specialties or procedures on the label without clinical data or a justified extension.

Equivalence with another robot

Another platform cited as equivalent despite differences in software, kinematics or instruments.

Learning curve not addressed

Results from expert centers presented without showing how outcomes hold for new users.

Instruments left out

Clinical data on the system that do not cover the instrument families placed on the market.

Software changes not traced

Evidence generated on earlier software versions without an assessment of what changed.

Generic PMCF plan

No registry or PMCF activity that follows outcomes by procedure and by surgeon experience.

Data sources

Where the clinical data can come from

Robotics files build evidence in stages. The clinical evaluation plan states which source answers which question at each stage.

Literature

Systematic search and appraisal

Published series on the system and on the state of the art by procedure, appraised with a documented protocol.

Early clinical data

First-in-human and feasibility

Early studies that establish safety and define the procedures and endpoints for later stages.

Registries

Procedure registries

Prospective registries that follow outcomes by procedure, surgeon and center, often the backbone of PMCF.

Clinical investigation

Pivotal or comparative study

A study against the state of the art when the claims go beyond what registries and literature can support.

How it runs

From gap review to notified body questions

Each step ends with a written output you can review. A senior reviewer challenges the file before it goes to your notified body.

Step 1

Gap review

Existing CER, claims, classification rationale and data inventory, with a written list of gaps.

Step 2

Evidence plan

Clinical evaluation plan, literature protocol and a data source for each open question.

Step 3

State of the art

Current surgical practice by procedure and its alternatives, used to judge the benefit and the acceptability of risk.

Step 4

Appraisal and writing

Data appraised and the CER written to Annex XIV Part A, traceable to each source.

Step 5

Reviewer challenge

Senior review against the findings notified bodies raise, before submission.

Step 6

Alignment and support

PMCF plan, SSCP where required and instructions for use aligned with the CER, and support with notified body questions.

No timeline is quoted before the gap review, because it depends on the data that already exists.

Deliverables

What you receive

Two fixed-scope reviews are available as a first step, each with a written deliverable. Full CER authoring is scoped after them.

Fixed scope

CER gap review

  • Review of the current CER and clinical evaluation plan
  • Claims checked against the evidence and the class
  • Equivalence and data-on-device assessment
  • Written gap list, ranked by review risk

Fixed scope

Response to notified body findings

  • Each finding mapped to the evidence that answers it
  • Written response text
  • Updated CER sections
  • Support during follow-up questions

Scoped after review

Full CER and related documents

  • Clinical evaluation plan and literature protocol
  • Clinical evaluation report
  • PMCF plan and PMCF evaluation report
  • SSCP where required
  • PMCF surveys where useful

Fixed-scope reviews are quoted after a scoping call. See the clinical evaluation report services page for other device types.

Track record

The numbers behind the method

Of the 56 studies ECLEVAR has delivered, 21 are PMCF studies and registries. The methods on this page come from that work.

56

Studies delivered

As of November 2026

By study phase

Studies by country

France18
Germany12
United Kingdom10
Italy8
Spain6
Nordic market3
Ireland2
Other5

A study running in several countries is counted once in each country.

400+

Devices assessed by former notified body reviewers now in ECLEVAR leadership

9

Clinical monitors (CRAs)

4

Project managers

3

Medical writers

3

Data management and biostatistics

2

Quality assurance

Clients

Medical device manufacturers we work with

Manufacturers of wound care products, implants, monitoring systems and dental devices use ECLEVAR for clinical investigations, PMCF and registries. More in our client success stories.

Client: RegenLab

Multicountry prospective PMCF in wound care

A two-cohort program in chronic wounds, diabetic foot ulcers and venous leg ulcers, run across European sites under one protocol and one data model.

160

participants

14

sites

5

European countries

Client: Perouse Medical, Vygon Group

Six registered observational studies across a vascular portfolio

ECLEVAR structured the program architecture and supports delivery. Intended evidence use: clinical evaluation and PMCF.

6

registered observational studies

3

device families

1,150+

subjects

5 years

follow-up

Team

The people who write and challenge your file

A senior team plans, writes and reviews the clinical evaluation, with U.S. clinical input from a robotic-assisted surgery launch.

Portrait of Michael McGuffey

Michael McGuffey

U.S. Clinical Consultant

Former clinical lead for final labeling on Medtronic's Hugo robotic-assisted surgery launch team, where he helped design surgeon training and proctoring and started a clinical registry for the platform.

Portrait of Pierre-Marie Boutanquoi

Pierre-Marie Boutanquoi

Head of Medical Writing

Clinical evaluation methodology, literature strategy, evidence architecture and regulatory gap analysis across therapeutic areas.

Portrait of Chems Hachani

Chems Hachani

Founder and CEO

Sets the evidence strategy with the sponsor and stays accountable for delivery from first scoping call to final report.

Portrait of Karina Schönborn

Karina Schönborn

Business Development Lead

Your first point of contact for scoping, budget scenarios and proposals.

ECLEVAR leadership includes former notified body reviewers; the full team is on the leadership page. Platinum Award · CVBF & MILO Health, xShare / EUCROF EHDS & Clinical Research Open Call. The award recognizes the submitted data use case and is not an evaluation of CRO services.

Questions

What manufacturers ask before they start

Do we need clinical data for every procedure on the label?

Each procedure needs clinical data or a justified extension from related procedures. Notified bodies look closely at indications that go beyond the procedures actually studied.

Can we claim equivalence with another surgical robot?

Rarely in practice. Equivalence requires comparable technical, biological and clinical characteristics, and differences in software, kinematics and instruments usually prevent it. Most robotics CERs rely on data on the system itself.

How should the learning curve appear in the CER?

As evidence, not as a caveat. The CER shows how outcomes change with experience, what training and proctoring are required, and how the PMCF plan follows results for new users.

Does the EU AI Act apply to our robot?

It can, when the system includes AI functions that qualify as high-risk under the AI Act. Each function is assessed individually, and the AI Act documentation and the clinical evaluation have to describe the same functions and performance.

Can U.S. clinical data support the EU CER?

Yes, when the system version, procedures, surgeon training and patient population are applicable to the EU claims. The CER describes the differences and their effect.

Who stays responsible for the clinical evaluation?

The manufacturer. ECLEVAR plans, writes and challenges the documents, and supports you during the review. The conclusions on benefit-risk and conformity remain yours.

Next step

Send the CER you have, or the findings you received

We will tell you which gaps matter most for your device's class and claims, and what it would take to close them.

We aim to respond within one business day. A confidentiality agreement can be signed before you share any document.

Share the file

Current CER, claims list, instructions for use and any notified body findings.

Gap review

A written list of gaps, ranked by review risk.

Scope and plan

An agreed scope for the CER work and the evidence plan behind it.