Software CER

Clinical evaluation for software as a medical device under the EU MDR

Clinical evaluation plans and reports for medical device software and AI-based tools, built on the three pillars of MDCG 2020-1: valid clinical association, technical performance and clinical performance. We check what your software claims to do, the class Rule 11 gives it, and the evidence that closes each pillar.

Three pillars the CER must close

Valid clinical association

Is the output linked to the clinical condition it targets, on the basis of literature or your own data?

Technical performance

Does the software produce accurate, reliable and reproducible output, including on data it has not seen?

Clinical performance

Does the output produce clinically relevant results in the intended population and setting of use?

A written gap review maps your existing evidence to each pillar before any writing starts.

Work aligned withEU MDR 2017/745 Annex XIVMDCG 2020-1MDCG 2019-11IEC 62304IEC 62366-1

Where you are

Three situations we are usually called in for

The scope depends on the stage of your file. Each engagement starts with a review of what exists, so the work covers the gap rather than the whole document by default.

First CE marking

A new software device: qualification and Rule 11 rationale checked, clinical evaluation plan, validation evidence mapped to the three pillars, and a CER written to Annex XIV Part A.

Update after a software change

A new algorithm version, a new indication or a new input source: what the change does to the evidence, and which validation has to be repeated.

Notified body findings

A deficiency list on the clinical evaluation: each finding mapped to the evidence that answers it, with a written response and updated CER sections.

Classification

Rule 11 decides how much evidence the CER must carry

Software that informs diagnostic or therapeutic decisions starts at Class IIa under Rule 11 of Annex VIII. The class rises with the severity of what those decisions can cause.

What the software doesMDR class under Rule 11What it changes for the CER
Provides information used to take decisions for diagnosis or therapyClass IIaClinical performance in the intended population, against the current standard of care or a reference method.
The same, where decisions could cause a serious deterioration of health or a surgical interventionClass IIbCloser scrutiny of clinical performance data, error analysis and the PMCF plan.
The same, where decisions could cause death or an irreversible deterioration of healthClass IIIA clinical investigation is expected unless an MDR exemption applies, and an SSCP is required.
Monitors physiological processesClass IIaTechnical and clinical performance of the monitoring in real conditions of use.
Monitors vital physiological parameters where variations could result in immediate dangerClass IIbPerformance at the thresholds that matter clinically, including alarm and alert behavior.
All other medical device softwareClass IA clinical evaluation is still required, proportionate to the claims.

Qualification comes first: MDCG 2019-11 helps decide whether the software is a medical device at all. Software that drives or influences a hardware device takes the class of that device.

Evidence

What each pillar needs in practice

Most software evidence comes from validation studies on well-characterized datasets. They have to be planned as carefully as a clinical study.

Reference standard

A defined ground truth for each output, with its own uncertainty documented, for example expert consensus or a confirmed diagnosis.

Independent test data

Validation on data that played no part in development, with its origin, period and sites described.

Representative population

Test data that reflect the intended patients, settings and input devices, with subgroups reported where performance may differ.

Clinically meaningful metrics

Sensitivity, specificity, predictive values or agreement, with confidence intervals and acceptance criteria set before the analysis.

Use in practice

Evidence on how users act on the output, including usability and, where it matters, the effect on clinical decisions.

Reviewer findings

What notified bodies flag in software CERs

These findings recur in software files. The gap review tests for each one before submission.

Pillars missing or merged

Technical performance data presented as if it also showed clinical performance.

Overlap between development and test data

Test data drawn from the same patients, sites or period as the training data, which inflates performance.

Unclear intended purpose

A claim that drifts between supporting a clinician and making a decision, with a classification that does not follow.

No acceptance criteria

Performance reported without criteria set in advance or justified against the state of the art.

Version gaps

Evidence generated on a software version other than the one under assessment, without a justification.

Generic PMCF plan

No plan to monitor real-world performance, drift or changes in the input data after release.

Data sources

Where the clinical data can come from

Most software files combine several sources. The clinical evaluation plan states which source closes which pillar.

Literature

Valid clinical association

Published evidence that the output is linked to the clinical condition, appraised with a documented protocol.

Retrospective data

Retrospective validation

Archived cases with a confirmed reference, used to measure technical and clinical performance without changing patient care.

Prospective data

Clinical performance study

A study in the intended setting when retrospective data cannot show clinical performance, run under ISO 14155 when it is a clinical investigation.

Post-market data

PMCF and real-world monitoring

Performance tracked after release, including drift, changes in input data and user feedback.

How it runs

From gap review to notified body questions

Each step ends with a written output you can review. A senior reviewer challenges the file before it goes to your notified body.

Step 1

Gap review

Existing CER, claims, classification rationale and data inventory, with a written list of gaps.

Step 2

Evidence plan

Clinical evaluation plan, literature protocol and a data source for each open question.

Step 3

State of the art

Current diagnostic or therapeutic practice and its alternatives, used to set acceptance criteria and judge benefit.

Step 4

Appraisal and writing

Data appraised and the CER written to Annex XIV Part A, traceable to each source.

Step 5

Reviewer challenge

Senior review against the findings notified bodies raise, before submission.

Step 6

Alignment and support

PMCF plan, SSCP where required and instructions for use aligned with the CER, and support with notified body questions.

No timeline is quoted before the gap review, because it depends on the data that already exists.

Deliverables

What you receive

Two fixed-scope reviews are available as a first step, each with a written deliverable. Full CER authoring is scoped after them.

Fixed scope

CER gap review

  • Review of the current CER and clinical evaluation plan
  • Claims checked against the evidence and the class
  • Equivalence and data-on-device assessment
  • Written gap list, ranked by review risk

Fixed scope

Response to notified body findings

  • Each finding mapped to the evidence that answers it
  • Written response text
  • Updated CER sections
  • Support during follow-up questions

Scoped after review

Full CER and related documents

  • Clinical evaluation plan and literature protocol
  • Clinical evaluation report
  • PMCF plan and PMCF evaluation report
  • SSCP where required
  • PMCF surveys where useful

Fixed-scope reviews are quoted after a scoping call. See the clinical evaluation report services page for other device types.

Track record

The numbers behind the method

Of the 56 studies ECLEVAR has delivered, 21 are PMCF studies and registries, and five are clinical studies of imaging software as a medical device under EU MDR. The methods on this page come from that work.

56

Studies delivered

As of November 2026

By study phase

Studies by country

France18
Germany12
United Kingdom10
Italy8
Spain6
Nordic market3
Ireland2
Other5

A study running in several countries is counted once in each country.

400+

Devices assessed by former notified body reviewers now in ECLEVAR leadership

9

Clinical monitors (CRAs)

4

Project managers

3

Medical writers

3

Data management and biostatistics

2

Quality assurance

Clients

Medical device manufacturers we work with

Manufacturers of wound care products, implants, monitoring systems and dental devices use ECLEVAR for clinical investigations, PMCF and registries. More in our client success stories.

Client: RegenLab

Multicountry prospective PMCF in wound care

A two-cohort program in chronic wounds, diabetic foot ulcers and venous leg ulcers, run across European sites under one protocol and one data model.

160

participants

14

sites

5

European countries

Client: Perouse Medical, Vygon Group

Six registered observational studies across a vascular portfolio

ECLEVAR structured the program architecture and supports delivery. Intended evidence use: clinical evaluation and PMCF.

6

registered observational studies

3

device families

1,150+

subjects

5 years

follow-up

Team

The people who write and challenge your file

A senior team plans the validation evidence, writes the clinical evaluation and challenges it before submission.

Portrait of Pierre-Marie Boutanquoi

Pierre-Marie Boutanquoi

Head of Medical Writing

Clinical evaluation methodology, literature strategy, evidence architecture and regulatory gap analysis across therapeutic areas.

Portrait of Sébastien Meier Piantanida

Sébastien Meier Piantanida

Head of Data Management and Biostatistics

Data architecture, EDC configuration, data quality control and statistical analysis for clinical performance studies.

Portrait of Chems Hachani

Chems Hachani

Founder and CEO

Sets the evidence strategy with the sponsor and stays accountable for delivery from first scoping call to final report.

Portrait of Karina Schönborn

Karina Schönborn

Business Development Lead

Your first point of contact for scoping, budget scenarios and proposals.

ECLEVAR leadership includes former notified body reviewers; the full team is on the leadership page. Platinum Award · CVBF & MILO Health, xShare / EUCROF EHDS & Clinical Research Open Call. The award recognizes the submitted data use case and is not an evaluation of CRO services.

Questions

What manufacturers ask before they start

Does our software need a clinical investigation?

Not always. Many software devices close the clinical performance pillar with retrospective validation on well-characterized data. Class III software is expected to have a clinical investigation unless an MDR exemption applies, and a prospective study may be needed at lower classes when retrospective data cannot show performance in the intended setting.

Is technical validation enough for a CER?

No. MDCG 2020-1 expects evidence of valid clinical association, technical performance and clinical performance. Technical validation shows that the software computes its output correctly; it does not show that the output is clinically meaningful in the intended population.

How do we handle new versions of the software?

Each change is assessed for its effect on performance and on the intended purpose. Some changes need repeated validation and an updated CER, and significant changes can require notified body involvement before release. The PMCF plan should set out how versions are monitored.

Does the EU AI Act change the clinical evaluation?

The AI Act adds its own requirements for AI-based medical device software, including data governance, transparency and human oversight. It does not replace the MDR clinical evaluation. Both sets of documents have to describe the same intended purpose, data and performance.

Can the clinical evaluation rely on data from outside the EU?

Yes, when the population, setting of use, input devices and clinical practice are shown to be applicable to the intended use in the EU. Differences are described in the CER and, where they matter, tested in subgroup analyses.

Who stays responsible for the clinical evaluation?

The manufacturer. ECLEVAR plans, writes and challenges the documents, and supports you during the review. The conclusions on benefit-risk and conformity remain yours.

Next step

Send the CER you have, or the findings you received

We will tell you which gaps matter most for your device's class and claims, and what it would take to close them.

We aim to respond within one business day. A confidentiality agreement can be signed before you share any document.

Share the file

Current CER, claims list, instructions for use and any notified body findings.

Gap review

A written list of gaps, ranked by review risk.

Scope and plan

An agreed scope for the CER work and the evidence plan behind it.