Wound dressing CER

Clinical evaluation reports for wound dressings under the EU MDR

CER writing, updates and notified body responses for wound dressings, from barrier and absorbent dressings to antimicrobial and animal-derived products. Every file starts from the same check: the claims on your label, the class they trigger and the clinical data that has to support them.

Three questions that set the evidence

What does the label claim?

Barrier and absorption, moisture management, healing support or antimicrobial action.

Which rule classifies it?

Rule 4 for most dressings. Rule 14 or Rule 18 when a medicinal substance or animal tissue is involved.

What data exists on your dressing?

Your own clinical data, an equivalent device, literature, or post-market and real-world data.

A written gap review answers all three before any writing starts.

Work aligned withEU MDR 2017/745 Annex XIVMEDDEV 2.7/1 rev 4MDCG 2020-5, 2020-6 and 2020-13ISO 14155:2026

Where you are

Three situations we are usually called in for

The scope depends on the stage of your file. Each engagement starts with a review of what exists, so the work covers the gap rather than the whole document by default.

First MDR CER

A new dressing or a first file under the MDR: clinical evaluation plan, literature protocol, state of the art, appraisal and benefit-risk, written to Annex XIV Part A.

MDD to MDR update

A legacy CER rebuilt for the MDR: data on the device itself, a current state of the art, claims checked against the evidence, and a PMCF plan that targets what remains open.

Notified body findings

A deficiency list on the clinical evaluation: each finding mapped to the evidence that answers it, with a written response and updated CER sections.

Classification

The class decides how much evidence the CER must carry

Most dressings fall under Rule 4 of Annex VIII. Two other rules move a dressing to Class III. The intended purpose, not the product category, decides which rule applies.

Intended purposeMDR rule and classWhat it changes for the CER
Mechanical barrier, compression or absorption of exudatesRule 4, Class IA clinical evaluation is still required. The evidence is proportionate to the claims and often draws on literature and post-market data.
Managing the micro-environment of injured skin, for example moisture balanceRule 4, Class IIaPerformance claims need clinical data on the dressing or an equivalent one, appraised against the state of the art.
Principally for wounds that have breached the dermis and can only heal by secondary intentRule 4, Class IIbChronic-wound claims draw closer scrutiny of the clinical data, the state of the art and the PMCF plan.
Incorporating a medicinal substance with an action ancillary to the dressingRule 14, Class IIIA clinical investigation is expected unless an MDR exemption applies. A medicines authority is consulted on the substance, and an SSCP is required.
Made from tissues of animal origin or their derivatives, for example some collagen dressingsRule 18, Class IIIThe same Class III requirements apply, together with the documentation on the animal-derived material.

Where more than one rule applies, the strictest one sets the class. The classification rationale is settled with your notified body, and the CER is written for the class that results.

Claims

Every claim on the label has to be carried by the CER

A claim that outruns its evidence is the most common reason a dressing file stalls. We map each claim to the data that supports it before writing. Our article on claims, classification and evidence explains the mechanism in detail.

Absorbs and retains exudate

Bench performance, plus clinical data or literature showing the function in the intended wound types.

Maintains a moist wound environment

Evidence that moisture management performs in use, and how it compares with the state of the art.

Supports healing of chronic wounds

Clinical outcomes such as wound area reduction or closure, in the indications named, against current standard care.

Antimicrobial or reduces bioburden

Evidence of the antimicrobial action at the wound, and a classification rationale that accounts for the substance.

Reduces pain, maceration or dressing changes

Patient-relevant outcomes measured with defined methods, not only clinician impressions.

Reviewer findings

What notified bodies flag in dressing CERs

These findings recur across wound dressing files. The gap review tests for each one before submission.

Equivalence not demonstrated

Technical, biological and clinical characteristics compared only in part, or another manufacturer's dressing cited without access to its data.

No clinical data on the device itself

Literature on the product category used in place of data on the specific dressing.

State of the art missing or dated

No current description of standard wound care and its alternatives, so the benefit cannot be judged.

Claims beyond the evidence

Healing or antimicrobial claims on the label that the clinical data do not support.

Generic PMCF plan

A plan that does not target the residual risks and open questions identified in the CER.

Inconsistent documents

CER, instructions for use, risk management, SSCP and labeling that describe the dressing or its claims differently.

Data sources

Where the clinical data can come from

Most dressing files combine several sources. The clinical evaluation plan states which source answers which question.

Literature

Systematic search and appraisal

A documented search protocol, appraisal criteria and data extraction, written so that another reviewer could reproduce them.

Equivalence

An equivalent device

Demonstrated on technical, biological and clinical characteristics, with the access to data that the MDR requires.

Post-market data

PMCF and real-world data

PMCF studies, surveys and registries, including retrospective U.S. wound records when they identify your dressing.

Clinical investigation

New clinical data

A pre- or post-market investigation when the other sources cannot carry the claims, as in the RegenLab program below.

How it runs

From gap review to notified body questions

Each step ends with a written output you can review. A senior reviewer challenges the file before it goes to your notified body.

Step 1

Gap review

Existing CER, claims, classification rationale and data inventory, with a written list of gaps.

Step 2

Evidence plan

Clinical evaluation plan, literature protocol and a data source for each open question.

Step 3

State of the art

Current wound care standards and alternatives, used to judge the benefit and the acceptability of risk.

Step 4

Appraisal and writing

Data appraised and the CER written to Annex XIV Part A, traceable to each source.

Step 5

Reviewer challenge

Senior review against the findings notified bodies raise, before submission.

Step 6

Alignment and support

PMCF plan, SSCP and instructions for use aligned with the CER, and support with notified body questions.

No timeline is quoted before the gap review, because it depends on the data that already exists.

Deliverables

What you receive

Two fixed-scope reviews are available as a first step, each with a written deliverable. Full CER authoring is scoped after them.

Fixed scope

CER gap review

  • Review of the current CER and clinical evaluation plan
  • Claims checked against the evidence and the class
  • Equivalence and data-on-device assessment
  • Written gap list, ranked by review risk

Fixed scope

Response to notified body findings

  • Each finding mapped to the evidence that answers it
  • Written response text
  • Updated CER sections
  • Support during follow-up questions

Scoped after review

Full CER and related documents

  • Clinical evaluation plan and literature protocol
  • Clinical evaluation report
  • PMCF plan and PMCF evaluation report
  • SSCP where required
  • PMCF surveys where useful

Fixed-scope reviews are quoted after a scoping call. See the clinical evaluation report services page for other device types.

Track record

The numbers behind the method

Of the 56 studies ECLEVAR has delivered, 21 are PMCF studies and registries. The methods on this page come from that work.

56

Studies delivered

As of November 2026

By study phase

Studies by country

France18
Germany12
United Kingdom10
Italy8
Spain6
Nordic market3
Ireland2
Other5

A study running in several countries is counted once in each country.

400+

Devices assessed by former notified body reviewers now in ECLEVAR leadership

9

Clinical monitors (CRAs)

4

Project managers

3

Medical writers

3

Data management and biostatistics

2

Quality assurance

Clients

Medical device manufacturers we work with

Manufacturers of wound care products, implants, monitoring systems and dental devices use ECLEVAR for clinical investigations, PMCF and registries. More in our client success stories.

Client: RegenLab

Multicountry prospective PMCF in wound care

A two-cohort program in chronic wounds, diabetic foot ulcers and venous leg ulcers, run across European sites under one protocol and one data model.

160

participants

14

sites

5

European countries

Client: Perouse Medical, Vygon Group

Six registered observational studies across a vascular portfolio

ECLEVAR structured the program architecture and supports delivery. Intended evidence use: clinical evaluation and PMCF.

6

registered observational studies

3

device families

1,150+

subjects

5 years

follow-up

Team

The people who write and challenge your file

A senior team plans, writes and reviews the clinical evaluation, with U.S. clinical input when the evidence plan uses U.S. data.

Portrait of Pierre-Marie Boutanquoi

Pierre-Marie Boutanquoi

Head of Medical Writing

Clinical evaluation methodology, literature strategy, evidence architecture and regulatory gap analysis across therapeutic areas.

Portrait of Chems Hachani

Chems Hachani

Founder and CEO

Sets the evidence strategy with the sponsor and stays accountable for delivery from first scoping call to final report.

Portrait of Dawn Heimer

Dawn Heimer, PhD

U.S. Clinical and Regulatory Consultant

Provides strategic input on U.S. medical-device clinical operations, regulatory considerations and real-world evidence programs.

Portrait of Karina Schönborn

Karina Schönborn

Business Development Lead

Your first point of contact for scoping, budget scenarios and proposals.

ECLEVAR leadership includes former notified body reviewers; the full team is on the leadership page. Platinum Award · CVBF & MILO Health, xShare / EUCROF EHDS & Clinical Research Open Call. The award recognizes the submitted data use case and is not an evaluation of CRO services.

Questions

What manufacturers ask before they start

Does a wound dressing need a clinical investigation under the MDR?

It depends on the class and on the data available. For Class III dressings, such as those with an ancillary medicinal substance or made from animal tissue, the MDR expects a clinical investigation unless one of its exemptions applies, for example equivalence under the conditions of Article 61(5). For Class I, IIa and IIb dressings, the clinical evaluation can rest on literature, equivalence and post-market data if together they are sufficient to support the claims.

Can we claim equivalence with another manufacturer's dressing?

Equivalence has to be shown on technical, biological and clinical characteristics, as described in MDCG 2020-5. For Class III devices, equivalence with another manufacturer's device also requires a contract giving ongoing full access to its technical documentation. In practice, equivalence with a competitor's dressing is often hard to support, and the gap review tells you early whether it is realistic.

Is our MDD-era CER still usable?

As a starting point. Legacy files usually need data on the device itself, an updated state of the art, a check that the claims still match the evidence, and a PMCF plan that targets what remains open. MDCG 2020-6 describes what notified bodies expect for legacy devices.

How is a silver or antimicrobial dressing classified?

It depends on what the antimicrobial does. If it is a medicinal substance acting on the wound with an action ancillary to the dressing, Rule 14 places the device in Class III and a medicines authority is consulted on the substance. The rationale is settled with your notified body before the CER is written, because the class sets the evidence the CER must carry.

Can U.S. real-world data support a European dressing CER?

It can contribute when the records identify your dressing, the population matches the intended purpose and the methods are fixed before analysis. The applicability of U.S. data has to be justified in the clinical evaluation. Whether the evidence is sufficient is the notified body's decision.

Who stays responsible for the clinical evaluation?

The manufacturer. ECLEVAR plans, writes and challenges the documents, and supports you during the review. The conclusions on benefit-risk and conformity remain yours.

Next step

Send the CER you have, or the findings you received

We will tell you which gaps matter most for your dressing's class and claims, and what it would take to close them.

We aim to respond within one business day. A confidentiality agreement can be signed before you share any document.

Share the file

Current CER, claims list, instructions for use and any notified body findings.

Gap review

A written list of gaps, ranked by review risk.

Scope and plan

An agreed scope for the CER work and the evidence plan behind it.